Heart rate: Observation |
| Requires Ocean Archetype Editor Build 1.0.1236 or above | Comments to Heather Leslie (Ocean) What do the symbols mean? | © Copyright openEHR Foundation 2007 |
Concept |
Archetype Id |
Structure |
|||
| The rate the heart is beating - either mechanically or electrically | Id: openEHR-EHR-OBSERVATION.heart_rate.v1 Reference model: EHR ADL, (ADL) |
|
| Data: TREE |
Concept |
Description |
Type |
Cardinality |
Values |
| The rate of the heart as beats per minute | Quantity | optional 0..1 |
Property = FREQUENCY
Units: /min, >= 0 - Limit decimal places = 0 |
|
| The rhythm of the heart beat | Coded text | optional 0..1 |
Regular
Irregular Irregularly irregular |
|
| The description of the rate and rythm | Text | optional 0..1 |
Free or coded text | |
| The pulse rate is present (implied true if rate > 0) | Boolean | optional 0..1 |
True, False |
|
|||||||||||
| State: LIST |
Concept |
Description |
Type |
Cardinality |
Values |
| The position of the patient when the heart rate was measured | Coded text | optional 0..1 |
Lying
Sitting Reclining Standing |
Events: HISTORY |
Events |
Description |
Constraints |
Values |
| Any event | * | PointInTime 0..* |
| Protocol: LIST |
Concept |
Description |
Type |
Cardinality |
Values |
| Device by which the heart rate was measured | Text | optional 0..1 |
Free or coded text |